SECTION 2: CIRCUIT REQUIREMENTS
This machine must have a ground prong in
the plug to help ensure that it is grounded.
DO NOT remove ground prong from plug
to fit into a two-pronged outlet! If the plug
will not fit the outlet, have the proper outlet
installed by a qualified electrician.
Electrocution or fire could
result if this machine is
not grounded correctly or
if your electrical configu
-
ration does not comply
with local and state codes.
Ensure compliance by
checking with a qualified
electrician!
Figure 1. Typical type 5-15 plug & receptacle.
110V Operation
Amperage Draw
The Model H7761 motor draws the following amps
under maximum load:
Motor Draw ...........................................2.6 Amps
Circuit Recommendations
We recommend connecting this machine to a
dedicated circuit with a verified ground (Figure
1), using the circuit breaker size given below.
Never replace a circuit breaker with one of higher
amperage without consulting a qualified electri
-
cian. If you are unsure about the wiring codes
in your area or you plan to connect your
machine to a shared circuit, you may create a
fire hazard—consult a qualified electrician to
reduce this risk.
Circuit Breaker .......................................
15 Amps
Plug/Receptacle Type
Included Plug Type ........................... NEMA 5-15
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
Extension Cords
We do not recommend the use of extension cords.
If you find it absolutely necessary:
• Use at least a 16 gauge cord that does not
exceed 50 feet in length!
• The extension cord must also contain a
ground wire and plug pin.
• A qualified electrician MUST size cords over