Grizzly G1005Z Drill User Manual


 
G1005Z Mill/Drill
-9-
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The Model G1005Z features a 110/220V motor
that is prewired for 110V and draws the following
amps under maximum load:
Motor Draw at 110V ............................... 12 Amps
Motor Draw at 220V ................................
6 Amps
Circuit Requirements
We recommend using a dedicated circuit for this
machine. You MUST connect your machine to a
grounded circuit that is rated for the amperage
given below. Never replace a circuit breaker on
an existing circuit with one of higher amper
-
age without consulting a qualified electrician to
ensure compliance with wiring codes
. If you are
unsure about the wiring codes in your area or
you plan to connect your machine to a shared
circuit, consult a qualified electrician.
110V Circuit ...........................................
15 Amps
220V Circuit ...........................................
15 Amps
Figure 2. NEMA 6-15 plug and outlet.
Plug Type
The Model G1005Z comes prewired with a NEMA
5-15 plug. If you wish to rewire the motor to 220V
we recommend using the following plug (see
Figure
2 for an example):
220V Plug & Receptacle ...................NEMA 6-15