Page 7SKU 97181 For technical questions, please call 1-800-444-3353.
GROUNDING
TO PREVENT
ELECTRIC SHOCK
AND DEATH FROM
INCORRECT GROUNDING
WIRE CONNECTION:
Check with a qualied
electrician if you are in doubt
as to whether the outlet is
properly grounded. Do not
modify the power cord plug
provided with the tool. Never
remove the grounding prong
from the plug. Do not use the
tool if the power cord or plug
is damaged. If damaged, have
it repaired by a service facility
before use. If the plug will not
t the outlet, have a proper
outlet installed by a qualied
electrician.
Grounded Tools: Tools with Three
Prong Plugs
3-Prong Plug and Outlet
1. Tools marked with “Grounding
and three prong grounding plug.
The plug must be connected to a
properly grounded outlet. If the tool
should electrically malfunction or
break down, grounding provides a
low resistance path to carry electricity
away from the user, reducing the risk
of electric shock. (See 3-Prong Plug
and Outlet.)
The grounding prong in the plug is 2.
connected through the green wire
inside the cord to the grounding
system in the tool. The green wire
in the cord must be the only wire
connected to the tool’s grounding
system and must never be attached
to an electrically “live” terminal. (See
3-Prong Plug and Outlet.)
The tool must be plugged into an 3.
appropriate outlet, properly installed
and grounded in accordance with all
codes and ordinances. The plug and
outlet should look like those in the
preceding illustration. (See 3-Prong
Plug and Outlet.)
NOTE: THIS BELT/Disc 4.
SANDER HAS A THREE-PRONG
GROUNDED PLUG.
Extension Cords
Grounded1.
extension cord. Double Insulated
tools can use either a two or three
wire extension cord.
As the distance from the supply 2.
outlet increases, you must use a
heavier gauge extension cord. Using
sized wire causes a serious drop in
voltage, resulting in loss of power and
possible tool damage.
(See Table A.) The smaller the
gauge number of the wire, the
greater the capacity of the cord. For
example, a 14 gauge cord can carry
a higher current than a 16 gauge
cord. (See Table A.)
WARNING