Ingersoll-Rand IRN250-300H-2S Air Compressor User Manual


 
IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S
http://air.irco.com
28
8.0 GENERAL INFORMATION
N55K N75K N75H N100H
General
Sound pressure level dB(A) * 75 75 75 75
Maximum ambient temperature ° C (° F) 46 (115) 46 (115) 46 (115) 46 (115)
Minimum ambient temperature ° C (° F) 1.7 (35) 1.7 (35) 1.7 (35) 1.7 (35)
Weight Kg (lbs) 1531 (3374) 1531 (3374) 1531 (3374) 1531 (3374)
Maximum pressure barg (psig) 10 (145) 10 (145) 10 (145) 10 (145)
Minimum pressure barg (psig) 4.5 (65) 4.5 (65) 4.5 (65) 4.5 (65)
Coolant capacity litres (US gal) 30 (8) 30 (8) 30 (8) 30 (8)
HAT switch setting ° C (° F) 120 (248) 120 (248) 120 (248) 120 (248)
Performance
Flow at 7.5 Barg (m3/min) 10.11 12.94
Flow at 8.5 Barg (m3/min) 9.29 12.15
Flow at 10 Barg (m3/min) 8.49 11.50
Flow at 100 psig (cfm) 372 479
Flow at 125 psig (cfm) 328 429
Flow at 140 psig (cfm) 306 413
Air Cooling System
Cooling air flow m3/min (cfm) 241 (8500) 241 (8500) 241 (8500) 241 (8500)
Maximum ∆P in air ducts Pa (inch WG) 124 (0.5) 124 (0.5) 124 (0.5) 124 (0.5)
Compressed air outlet ∆T° C (° F) 8 (15) 8 (15) 8 (15) 8 (15)
Water Cooling System
Cooling (clean) water flow l/min (US
gallon/min) @ 10 ° C (50 ° F) / 32 ° C (90
° F)
51/38
(13.5 /10)
95/46
(25 /12)
51/38
(13.5/10)
95/46
(25/12)
Maximum ∆P in air ducts Pa (inch WG) 62 (0.25) 62 (0.25) 62 (0.25) 62 (0.25)
Compressed air outlet ∆T ° C (° F) 14 (25) 14 (25) 14 (25) 14 (25)
Main Power Circuit A/C (W/C) ***
Package full load current at 220V (A) ** 208 (196) 208 (196)
Package full load current at 400V (A) ** 110 (104) 144 (138)
Package full load current at 460V (A) ** 100 (94) 131 (125)
Package full load current at 575V (A) ** 82 (78) 108 (103)
Max fuse size @ 220V (A) 300 400 300 400
Max fuse size @ 400V (A) 150 200 150 200
Max fuse size @ 460V (A) 150 200 150 200
Max fuse size @ 575V (A) 125 150 125 150
Fuse type Fast acting class J, T or semiconductor type, current limiting
interrupt rating 200, 000 Amps RMS SYM.
Heater Circuit
110V Single Phase Rating (A) 4 4 4 4
230V Single Phase Rating (A) 4 4 4 4
Fuse type General purpose
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable
size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)