8.0 GENERAL INFORMATION
N90K N110K N125H N150H
General
Sound pressure level dB(A) * 75 75 75 75
Maximum ambient temperature ° C (° F) 46 (115) 46 (115) 46 (115) 46 (115)
Minimum ambient temperature ° C (° F) 1.7 (35) 1.7 (35) 1.7 (35) 1.7 (35)
Weight Kg (lbs) 3175 (6985) 3175 (6985) 3175 (6985) 3175 (6985)
Maximum pressure barg (psig) 10 (145) 10 (145) 10 (145) 10 (145)
Minimum pressure barg (psig) 4.5 (65) 4.5 (65) 4.5 (65) 4.5 (65)
Coolant capacity litres (US gal) 91 (24) 91 (24) 91 (24) 91 (24)
HAT switch setting ° C (° F) 120 (248) 120 (248) 120 (248) 120 (248)
Performance **
Flow at 7.5 Barg (m3/min) 17.1 20.0
Flow at 8.5 Barg (m3/min) 15.3 19.2
Flow at 10 Barg (m3/min) 14.0 17.5
Flow at 100 psig (cfm) 655 739
Flow at 125 psig (cfm) 571 670
Flow at 140 psig (cfm) 524 610
Air Cooling System
Cooling air flow m3/min (cfm) 382 (13500) 382 (13500) 382 (13500) 382 (13500)
Maximum ∆P in air ducts Pa (inch WG) 124 (05) 124 (05) 124 (05) 124 (05)
Compressed air outlet ∆T ° C (° F) 8 (15) 8 (15) 8 (15) 8 (15)
Water Cooling System
Cooling (clean) water flow l/min (US
gallon/min) @ 10° C (50° F) / 32° C (90° F)
84/65
(22/17)
95/72
(25/19)
84/65
(22/17)
95/72
(25/19)
Maximum ∆P in air ducts Pa (inch WG) 62 (0.25) 62 (0.25) 62 (0.25) 62 (0.25)
Compressed air outlet ∆T ° C (° F) 14 (25) 14 (25) 14 (25) 14 (25)
Main Power Circuit A/C (W/C) ***
Package full load current at 400V (A) ** 182 (170) 218 (206)
Package full load current at 460V (A) ** 170 (160) 200 (190)
Package full load current at 575V (A) ** 140 (132) 165 (157)
Max fuse size @ 380V − 415V (A) 250 350
Max fuse size @ 440V − 480V (A) 250 250
Max fuse size @ 550V − 575V (A) 200 200
Fuse type Fast acting class J, T or semiconductor type, current limiting
interrupt rating 200, 000 Amps RMS SYM.
Heater Circuit
110V Single Phase Rating (A) 4 4 4 4
230V Single Phase Rating (A) 4 4 4 4
Fuse type General purpose
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable
size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)