Ives 232TGSL Impact Driver User Manual


 
3
LUBRICATION
Ingersoll--Rand No. 50 Ingersoll--Rand No. 100
Always use of an air line lubricator. We recommend the
following Filter--Regulator--LubricatorUnit (FRL):
Inside USA use FRL unit # C28--04--FKG0--28
Outside USA use FRL unit # C28--C4--FKG0
After each eight hours of operation, if anairline
lubricator is not used, remove the Oil Chamber Plug (17)
and fillthe oil chamberwith Ingersoll--Rand No. 50Oil.
After each eight hours of operation, or asexperience
indicates, inject about 4 cc of the Ingersoll--Rand No. 100
Greaseinto the Grease Fitting (16).
INSTALLATION
(Dwg. TPD905--2)
F
L
R
Main
L
ine(s)InnerØ
tobe 3X Sizeof
AirTool’sInlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut--Off
Valve
Regulator
Filter
Compressor
FRL
DrainRegularly
Branch
L
ine(s)InnerØ
tobe 2X Sizeof
AirTool’sInlet Ø
SPECIFICATIONS
Model
Handle
Drive
Recommended Torque Range
I.D.
Type
inches
ftSlb (NSm)
232TGSL
pistol
1/2 sq.
40--400 (64--542)