Lincoln IM985 Welder User Manual


 

&!'

&*"(P)#(
CAUTION :
N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPICATIONS. SEE OPERATING MANUAL.
75
32
31
41
42
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. SPLICE LEADS AND INSULATE.
THE ENGINE WELDER OPERATING MANUAL.
GND
31
4
21
B
C
A
14 PIN
AMPHENOL
TO WORK
TO WORK
ELECTRODE
TO WIRE FEED UNIT
ELECTRODE CABLE
WIRE
FEEDER
K196
K867 UNIVERSAL
ADAPTER PLUG
INPUT CABLE
S23989
ENGINE WELDERS / K867 / LN-8 CONNECTION DIAGRAM
7-2000
2
4
76
77
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE SELECTOR SWITCH TO "WIRE WELDING CV".
SPARE
82
Only qualified personnel should install,use
81
before servicing.
or service this equipment.
Keep away from moving parts.
N.C.
Keep guards in place.
}
Disconnect NEGATIVE (-) BATTERY LEAD
Do not touch electrically live parts.
21
Do not operate with panels open.
GND
N.D.
32
2
WARNING
}
LN-8
CAUTION :
N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE
APPICATIONS. SEE OPERATING MANUAL.
75
32
31
41
42
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. SPLICE LEADS AND INSULATE.
THE ENGINE WELDER OPERATING MANUAL.
GND
31
4
21
B
C
A
14 PIN
AMPHENOL
TO WORK
TO WORK
ELECTRODE
TO WIRE FEED UNIT
ELECTRODE CABLE
WIRE
FEEDER
K196
K867 UNIVERSAL
ADAPTER PLUG
INPUT CABLE
S23989
ENGINE WELDERS / K867 / LN-8 CONNECTION DIAGRAM
7-2000
2
4
76
77
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE
AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE
DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN
N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE SELECTOR SWITCH TO "WIRE WELDING CV".
SPARE
82
Only qualified personnel should install,use
81
before servicing.
or service this equipment.
Keep away from moving parts.
N.C.
Keep guards in place.
}
Disconnect NEGATIVE (-) BATTERY LEAD
Do not touch electrically live parts.
21
Do not operate with panels open.
GND
N.D.
32
2
WARNING
}
LN-8