INSTALLATION
V205-T DC & V205-T AC/DC TIG
A-4
230V INPUT
The equipment is provided with a 230/115V cable,
6.6ft.(2m) in length with a 230V 6-50P attachment
plug.
The Invertec V205-T performs best when connected
to 230VAC inputs. This input allows full output of the
machine (200 amps).
115V INPUT
A suitable 115V attachment plug must be installed on the
power cord to use the V205-T with a 115V input supply.
The rated output of the V205-T is available when con-
nected to a 30A branch circuit. When connected to a
branch circuit with lower amp rating, lower welding cur-
rent and duty cycle must be used. An output guide is pro-
vided below. The values are approximate and must be
adjusted downward if the fuse or circuit breaker trips off.
Other loads on the circuit and fuse/circuit breaker char-
acteristics will affect the available output. Do not exceed
these welding conditions:
15A branch circuit
10% duty cycle
Stick: 75A
TIG: 105A
20A branch circuit
10% duty cycle
Stick: 90A
TIG: 130A
ATTACHMENT PLUG INSTALLATION
Connect the white (neutral) wire under terminal clamp
with silver screw, and black (hot) wire under terminal
clamp with brass screw. Connect green wire under
terminal clamp with green screw.
Failure to wire as instructed may cause personal
injury or damage to equipment. To be installed
or checked by an electrician or qualified person
only.
---------------------------------------------------------------------------
In all cases, the green or green/yellow grounding wire
must be connected to the grounding pin of the plug, usu-
ally identified by a green screw.
Attachment plugs must comply with the Standard for
Attachment Plugs and Receptacles, UL498.
The product is considered acceptable for use only when
an attachment plug as specified is properly attached to
the supply cord.
For use on engine drives, keep in mind the above
input draw restrictions and the following precaution.
ENGINE DRIVEN GENERATOR
The Invertec V205-T DC & V205-T AC/DC can be
operated on engine driven generators as long as the
230 volt auxiliary meets the following conditions:
• The AC waveform peak voltage is below 400 volts.
• The AC waveform frequency is between 45 and
65Hz.
The following Lincoln engine drives meet these condi-
tions when run in the high idle mode:
• Ranger 250, 250 LPG, 305 G, 305 D*
• Vantage 300, 400, 500 & Air Vantage 500*
Some engine drives do not meet these conditions
(e.g. Miller Bobcats, etc). Operation of the Invertec
V205-T AC/DC is not recommended on engine drives
not conforming to these conditions. Such drives may
deliver unacceptably high voltage levels to the
Invertec power source.
* Ranger and Vantage Engine Drives require the full
KVA Adapter Kit (K1816-1)
WARNING