Lincoln Electric 205-TAC/DCTIG Welding System User Manual


 
A-5
INSTALLATION
V205-T DC & V205-T AC/DC TIG
A-5
This unit does not include a TIG torch, but one may be
purchased separately. The accessories section of this
manual lists a number of Lincoln Electric TIG torches,
and TIG Torch Starter Packs that are recommended
for use with this machine; however, any similar TIG
torch can be used. To attach the Twist-Mate Plug to a
Lincoln Torch, slide the rubber boot onto the torch
cable (enlarge the boot opening if necessary), screw
the fitting on the torch cable into the brass connector
snugly and slide the boot back over the brass connec-
tor.
OUTPUT CONNECTION FOR STICK
WELDING (FIGURE A.2)
First determine the proper electrode polarity for the
electrode to be used. Consult the electrode data for
this information. Then connect the output cables to
the output terminals corresponding to this polarity.
For instance, for DC(+) welding, connect the electrode
cable (which is connected to the electrode holder) to
the “+” output terminal and the work cable (which is
connected to the work clamp) to the “-” output termi-
nal. Insert the connector with the key lining up with
the keyway, and rotate clockwise; until the connection
is snug. Do not over tighten.
TIG ADAPTER
RETAINING COMPOUND
STRAIN RELIEF BOOT
TIG TORCH POWER CABLE WITH GAS FITING
+
-
+
-
FIGURE A.2
WORK CABLE
WORK CABLE
WORK CLAMP
STICK ELECTRODE
HOLDER
WORK CABLE
TIG TORCH
OUTPUT CONNECTIONS
ELECTRIC SHOCK can kill.
• Keep the electrode holder, TIG
torch and cable insulation in good
condition and in place.
• Do not touch electrically live parts
or electrode with skin or wet cloth-
ing.
• Insulate yourself from work and ground.
• Turn the input line Switch on the Invertec V205-T
DC & V205-T AC/DC “off” before connecting or
disconnecting output cables or other equipment.
-----------------------------------------------------------
WARNING
OUTPUT AND GAS CONNECTION FOR
TIG WELDING (FIGURE A.1)
The TIG Torch Twist-Mate and work cable Twist-Mate
Connectors are supplied with the welder. To connect
the cables, turn the PowerSwitch “OFF”.
Connect the
torch cable Twist-Mate plug into the DC(-)
Electrode/Gas Output Receptacle on the front of the
welder and turn it clockwise until snug,(Do not
Overtighten). This is a quick connect terminal and also
provides the gas connection for the shielding gas to
the torch.
To avoid receiving a high frequency shock, keep
the TIG torch and cable Insulation in good condi-
tion.
___________________________________________
WORK CABLE CONNECTION
Next, connect the work cable to the “+” output terminal
in the same way.
To minimize high frequency interference, refer to
Machine Grounding and High Frequency
Interference Protection section of this manual for the
proper procedure on grounding the work clamp and
work piece.
WARNING
FIGURE A.1