Lincoln Electric LN-9F GMA Welder User Manual


 
*(%+")%%*$
 
"$#1=4"$#-9A55545A
&(%"#)
)/#&*%#)
Gun trigger will not feed wire. Digital
meter is not lit.
&%))"()%
#) +)*#$*)
1. Check to see if the circuit
breaker is tripped. Reset the
circuit breaker. See the topic
"Circuit Breaker" in the
Operation section.
2. Check to see if the power supply
fuse is blown. Replace the fuse.
See the topic "Power Supply
Fuse" in the Operation section.
3. Check to see if there is 115 VAC
supply from the power source.
Check that power source is "on".
If so, check the power source AC
fuse.
4. The control cable may be faulty.
Check or replace.
(%##$
%+()%*%$
If all recommended possible
areas of misadjustment have
been checked and the problem
persists, contact your local
Lincoln Authorized Field Service
Facility.