Gun trigger will not feed wire. Meter
is "on" and reads SET value of
VOLTS or WIRE SPEED.
&%))"()%
#) +)*#$*)
1. Check to see if the grounding
lead protector (GLP) circuit has
tripped. Clear any fault
discovered between the electrode
circuit and the wire feeder frame
and then press the "GLP Reset"
button. See the topic "Avoiding
Grounding Lead Protector
Shutdown" in the Operation
section.
2. Check the gun trigger circuit.
(%##$
%+()%*%$
If all recommended possible
areas of misadjustment have
been checked and the problem
persists, contact your local
Lincoln Authorized Field Service
Facility.
If for any reason you do not understand the test procedures or are unable to perform the necessary tests/repairs
safely, contact your ;>31;1DC8>A9I54695;4B5AE9356139;9CH before you proceed.
-($&(%"#)
+*%$
Observe Safety Guidelines
detailed in the beginning of this manual.
*(%+")%%*$+