Lincoln Electric SVM168-B Welder User Manual


 
RANGER® 10,000 & RANGER® 10,000 PLUS
TROUBLESHOOTING & REPAIR
F-60 F-60
RETEST AFTER REPAIR
Retest a machine:
If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics.
OR
If you repair or replace any electrical components.
ENGINE OUTPUT
Mode No Load RPM Load RPM
Low Idle 2150-2250 NA
High Idle 3700-3750 3100-3600
WELDER DC OUTPUT
1
Output Control Range Switch Open Circuit Load Volts Load Amps
Volts
Maximum Maximum 65 - 72 21 - 26.5 205 - 240
WELDER AC OUTPUT
1
Output Control Range Switch Open Circuit Load Volts Load Amps
Volts
Maximum Maximum 73 - 80 25 - 32 225 - 275
WELDER CV OUTPUT
1
Output Control Range Switch Open Circuit Load Volts Load Amps
Volts
Maximum Wire Feed CV 29 - 33 19 - 22 200 - 220
AUXILIARY POWER RECEPTACLE OUTPUT
1
230 Volt Receptacle 115 Volt Receptacle
2
Open Circuit Load Volts Load Amps Open Circuit Load Volts Load Amps
Voltage Voltage
246 - 264 216 - 250 34 - 41.5 123- 132 114 - 126 35 - 42
FIELD AMPS AND VOLTS
Slip Ring Volts Field Amps
28.0 - 46.0 VDC 6.5 - 7.5 VDC
1
OUTPUT CONTROL switch set at MAXIMUM (position 10).
2
Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC