Lincoln Electric SVM173-A Welding System User Manual


 
TROUBLESHOOTING & REPAIR
F-45 F-45
POWER WAVE 455M/MSTT
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
RECEPTACLE
S7
STT
POWER
WAVE
FIGURE F.14 – RECEPTACLE S7 TRIGGERED
STT CURRENT TRANSDUCER TEST (CONTINUED)
5. Turn on the Power Wave 455M. Check for
the correct DC supply voltage to the current
transducer at plug J8.
A. Pin 8 (lead 812+) to pin 7 (lead 816-)
should read +15 VDC.
B. Pin 4 (lead 813-) to pin 7 (lead 816+)
should read -15 VDC.
If the DC supply voltages are not present,
the control board may be faulty.
6. If both of the supply voltages are low or
missing, check the associated leads
between plug J8 and current transducer plug
P90 and the Control Board.
NOTE: The machine can be triggered by
jumpering pin 1 to pin 2 at receptacle
S7. See Figure F. 14.
7. With the Power Wave 455M triggered, check
the feedback voltage from the current trans-
ducer. The current feedback voltage can be
read at plug J8 on the Control Board.
A. Pin 5 (lead 811) to pin 7 (lead 816)
should read 0.4 VDC (machine loaded
to 50 amps).