Figure 8 shows clockwise and counter-clockwise motor rotation.
Figure 8. Clockwise and Counter-Clockwise Motor Rotation
When connecting the encoder wiring to your MID-7604/7602, useshielded
wire of at least 24 AWG. Analog noise filters filter the encoder inputs in the
MID-7604/7602. You must use cables with twisted pairs and an overall
shield for improved noise immunity and enhanced encoder signal integrity.
Figure 9 shows twisted pairs in a shielded cable.
Figure 9. Shielded Twisted Pairs
Note
If you use an unshielded cable, noise can corrupt the encoder signals, resulting in
lost counts, reduced accuracy, and other erroneous encoder and controller operation.
CCW
CW
Shield
+5 V
Encoder Index
Encoder Index
Encoder B
Encoder B
Encoder A
Drain
Encoder A
Digital
Ground