Outback Power Systems GS8048 Welding System User Manual


 
Specifications
48 900-0020-01-00 Rev A
Table 11 GS8048 Inverter Settings
Field Item Default Minimum Maximum
Aux Control Off Off, Auto or On
Aux Mode Vent Fan
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
DC Divert, IEEE, Source Status, AC Divert
(Load Shed) ON: Batt >
56 Vdc 40 Vdc 72 Vdc
(Load Shed ON) Delay
30 Secs 6 Secs 1500 Secs
(Load Shed) OFF: Batt <
56 Vdc 48 Vdc 72 Vdc
(Load Shed OFF) Delay
18 Secs 6 Secs 1500 Secs
(Gen Alert) ON: Batt <
44 Vdc 40 Vdc 56 Vdc
(Gen Alert ON) Delay
30 Secs 6 Secs 1500 Secs
(Gen Alert) OFF: Batt >
56 Vdc 48 Vdc 72 Vdc
(Gen Alert OFF) Delay
30 Secs 6 Secs 1500 Secs
(Vent Fan) ON: Batt >
56 Vdc 48 Vdc 72 Vdc
(Vent Fan) Off Delay
18 Secs 6 Secs 1500 Secs
(DC Divert) ON: Batt >
56 Vdc 48 Vdc 72 Vdc
(DC Divert ON) Delay
30 Secs 6 Secs 1500 Secs
(DC Divert) OFF: Batt <
44 Vdc 40 Vdc 56 Vdc
(DC Divert OFF) Delay
30 Secs 6 Secs 1500 Secs
(AC Divert) ON: Batt >
56 Vdc 48 Vdc 72 Vdc
(AC Divert ON) Delay
30 Secs 6 Secs 1500 Secs
(AC Divert) OFF: Batt <
44 Vdc 40 vdc 56 Vdc
Auxiliary Output
(AC Divert OFF) Delay
30 Secs 6 Secs 1500 Secs
Aux Control Off Off, Auto or On
Aux Mode Gen Alert
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
DC Divert, IEEE, Source Status, AC Divert
(Load Shed) ON: Batt >
56 Vdc 40 Vdc 72 Vdc
(Load Shed ON) Delay
30 Secs 6 Secs 1500 Secs
(Load Shed) OFF: Batt <
56 Vdc 48 Vdc 72 Vdc
(Load Shed OFF) Delay
18 Secs 6 Secs 1500 Secs
(Gen Alert) ON: Batt <
44 Vdc 40 Vdc 56 Vdc
(Gen Alert ON) Delay
30 Secs 6 Secs 1500 Secs
(Gen Alert) OFF: Batt >
56 Vdc 48 Vdc 72 Vdc
(Gen Alert OFF) Delay
30 Secs 6 Secs 1500 Secs
(Vent Fan) ON: Batt >
56 Vdc 48 Vdc 72 Vdc
(Vent Fan) Off Delay
18 Secs 6 Secs 1500 Secs
(DC Divert) ON: Batt >
56 Vdc 48 Vdc 72 Vdc
(DC Divert ON) Delay
30 Secs 6 Secs 1500 Secs
(DC Divert) OFF: Batt <
44 Vdc 40 Vdc 56 Vdc
(DC Divert OFF) Delay
30 Secs 6 Secs 1500 Secs
(AC Divert) ON: Batt >
56 Vdc 48 Vdc 72 Vdc
(AC Divert ON) Delay
30 Secs 6 Secs 1500 Secs
(AC Divert) OFF: Batt <
44 Vdc 40 vdc 56 Vdc
Auxiliary
Relay
(AC Divert OFF) Delay
30 Secs 6 Secs 1500 Secs
Inverter Stacking
Stack Mode Master Master, Slave
Master Power Save Level
0 0 31
Power Save
(in Stacking Menu)
Slave Power Save Level
1 1 31
Grid-Tie Enable Y Y or N
Sell Voltage
52 Vdc 40 Vdc 60 Vdc
Grid-Tie Sell
Grid-Tie Window IEEE IEEE or user
Input Voltage
0 -7 7
Output Voltage
0 -7 7
Calibrate
Battery Voltage
0 -0.8 0.8