Shindaiwa DGW310DMC Welder User Manual


 
22
7-2 Stopping
1. Turn the breaker to OFF .
2 .Turn the slow-down switch to ON .
3. Keep the engine (cool down) for about 5 minutes.
4. Turn the starter switch to STOP .
5. After the engine stops, turn the fuel lever to CLOSE .
Caution
When the engine will not stop in spite of turning the starter switch to STOP, turn the fuel lever to CLOSE,
then the engine will stop in a few minutes. In this case, be sure to consult with our authorized distributor
or our service section and ask to repair.
8-1. Selection – Welding Cable
Select the cable in proper gauge, based on the allowable amperage and the length, per the table shown
below.
The welding capacity is to reduce if the small gauge or long cable is used.
Caution
Welding cables should be used unstrained. When the welding cable are used in swirl, the welding
capacity is to reduce
Size of Cable Unit mm
2
Return
Length
20m 30m 40m 60m 80m 100m
Current
300A 30 38 50 80 100 125
250A 22 30 38 60 80 100
200A 22 30 30 50 60 80
150A 22 22 22 38 50 60
100A 22 22 22 30 30 38
8. Welding Operation