The circuit breakers react on the AC power supply circuit only. In the simultaneous use of welding and
generating, there may be happen overload to the engine. Refer to the following table and limit AC power use.
Limitation of AC Power Supply in the simultaneous use of welding and generating (60Hz)
DGW310DMC
Welding Output AC Power Output
Rod/Current Select 3-P Output (PF 0.8) 1-P Output
φ2.0mm/60A Dual 9.3kVA 7.4kVA
φ2.6mm/120A Dual 7.2kVA 5.7kVA
φ3.2mm/140A Dual 6.4kVA 5.1kVA
φ4.0mm/170A Dual 5.2kVA 4.1kVA
φ5.0mm/240A Single 2.0kVA 1.6kVA
φ6.0mm/300A Single 0kVA 0kVA
The 1-P figure shown is the total output of 1-P 100/110V and 200/220V.
DGW310MC
Welding Output AC Power Output
Rod/Current Select 3-P Output 1-P Output
φ2.0mm/60A Regular
9.3kVA 7.4kVA
φ2.6mm/120A Regular
7.2kVA 5.7kVA
φ3.2mm/140A Regular
6.4kVA 5.1kVA
φ4.0mm/170A Regular
5.2kVA 4.1kVA
φ5.0mm/240A Regular
2.0kVA 1.6kVA
φ6.0mm/300A Regular
0kVA 0kVA
The 1-P figure shown is the total output of 1-P 100/110V and 200/220V.
Caution
Simultaneous use of Welding and AC Power is NOT available.
Avoid simultaneous use in the case high welding quality is required.
10. Simultaneous use of Generating and Welding