Shindaiwa DGW310DMC Welder User Manual


 
33
Check Time
Every Every Every Every Every
Check Items Startup
At 50 hrs
100 hrs
200 hrs 400 hrs 1000 hrs 2000 hrs
Clean Radiator Fin
16
(Outer)
17
Clean Radiator (Inner)
Change Fuel Hose, Coolant
Hose, Oil Hose,
18
Anti
-Vibration Rubber
Or 2 yrs
Adjust/Plane Engine
19
Valve Clearance
Adjust Plane
20
Check/Adjust Injection Nozzle
Check/Adjust Injection
21
Nozzle
(1)Change Engine Oil
1
st
At 50 hrs
2
nd
or after Every 100 hrs
1 Remove the oil plug.
2 Remove the oil drain plug and
drain the oil completely.
3 Reinstall the oil drain plug tightly.
4 Checking the oil level by the oil level
gauge, replenish oil up to the UPPER level though the oil inlet.
(About 38 Liter)
5 Reinstall the oil plug tightly.
Caution
Refer to 6-1. Check Engine Oil to decide Engine Oil.
Change the packing to the new one in the oil drain plug whenever changing engine oil.
Packing No.: C09058961 (Kubota)
After reinstalling the oil drain plug tightly, keep the engine drive for a while to check no engine oil leakage
and then stop the engine.
Oil Drain Plug
Oil Inlet Oil Gauge
Oil Gauge