Woodstock W1813 Sander User Manual


 
-34-
N(/(*(/Fg\e<e[N`[\9\ckJXe[\i
J<IM@:<
8`i Gi\jjli\JX]\kp
Jn`kZ_
The sanding motor safety brake and the sanding oscilla-
tion system require at 57–60 PSI of air pressure connected
to the machine to operate. The air pressure safety switch
(see =`^li\*)) measures the amount of air pressure flow-
ing into the machine. If the air pressure is not adequate,
the air pressure safety switch will not allow power to flow
to the sander.
The air pressure safety switch was calibrated and set at
the factory and should not require any further adjust-
ment. However, we recommend that you verify the set-
tings.
The red pointer on the sensitivity scale should be set at
"0" on the scale, which is adjusted with the sensitivity
adjustment screw shown in =`^li\*). The minimum air
pressure scale on the right of the scale window should
read 4kg/cm
2
, which is adjusted with the adjustment
screw on the top of the switch.
=`^li\*)%Air pressure safety switch.
Sensitivity Adjustment Screw
Minimum
Air Pressure
Adjustment Screw
& Scale
Sensitivity Scale
The safety devices on this machine are
there for your safety. DO NOT operate
this sander if any safety device is dam-
aged or is not operating correctly. Oth-
erwise, serious personal injury could
result.