10.10 Specifying Expert User Mode Functions
10
10-85
Utility Mode Operations Chapter 10
7 Touch [1st Tray].
8 Press the [Start] key.
The test pattern is
printed on 11 × 17-size
paper.
9 Check that the left margin of the
test pattern for the second side is
between 2.5 mm and 3.5 mm.
If the left margin is within the
specified range, skip to step 14.
10 If the left margin for the second side is less than 2.5 mm, touch to specify
the desired positive adjustment (between +0.1 mm and +3.0 mm).
11 If the left margin for the second side is more than 3.5 mm, touch to specify
the desired negative adjustment (between -0.1 mm and -3.0 mm).
12 Press the [Start] key.
The adjusted test pattern is printed on 11 × 17-size paper.
13 Check the print result.
Make sure that the left margin for the second side is adjusted to between 2.5
mm and 3.5 mm.
If more adjustment is necessary, return to step 10 and repeat the adjustment
procedure.
14 Touch [Enter].
15 Touch [Exit] in the next three screens that appear.
The main screen appears again.
c: 3.0 mm ± 0.5 mm
c