Epson DW073 Laser Level User Manual


 
12
English
6. Follow the instructions for leveling the laser.
TIP:
Remember the
front leveling knob controls the movement of the bubble in the
front vial, the side leveling knob controls the movement of the
bubble in the side vial.
7. Turn the laser on if not on already; adjust rotation speed and con-
trols as needed.
Horizontal Leveling
1. Set the laser on a relatively smooth and
level surface such as a Tripod or pre-
pare the laser level to be attached to
wall track using the built-in Wall Mount
feature. See “Wall Mount” section.
2. Use the Two-Position Pivoting Head
Adjustment Lever to pivot the laser
head to a level setting for projecting a
horizontal reference beam. In this
position the Manual Head Rotation
Button (A) should be pointing up
towards the ceiling or sky.
3. The leveling knobs (B) control the
orientation of the laser head on the metal leveling plates and effect
the movement of the bubbles in the vials (C). When the laser level
is placed in a level position the front leveling knob controls the
movement of the bubble in the front vial. The side leveling knob
controls the movement of the bubble in the side vial. NOTE: The
same leveling rules apply to the tool when being used with the
Wall Mount feature.
4. To level the laser, the bubbles in both the front and side vials need
to be centered within the vials.
TIP:
The more accurately you can
center the bubbles within the vials the more accurate your hori-
zontal laser reference beam will be.
5. To level the laser, turn the leveling knob towards the bubble until
the bubble is centered in the vial.
TIP:
To move the bubble in the
front vial to the right, turn the front leveling knob to the left. To
A
B
C
move the bubble in the front vial to the left, turn the leveling knob
to the right. Repeat the procedure for the side vial.
6. Turn the laser on if not on already; adjust rotation speed and con-
trols as needed.
7. To project a level laser reference plane, adjust the rotation speed
for preferred visibility. Remember: Slow Speed = Bright Beam;
Fast Speed = Solid Beam.
Vertical Plumbing
1. Set the laser on a relatively
smooth and level surface. The
tool should be positioned on the
large base plate under the battery
pack. Utilize the Base Leveling
Knob (A) to roughly position the
laser.
2. Use the Two-Position Pivoting
Head Adjustment Lever to pivot
the laser head to a plumb setting for projecting a vertical reference
beam. In this position the pivoting laser head should be directly
over the Wall Mount Clamp and the Control Panel should be fac-
ing up towards the ceiling or sky.
3. To plumb the laser, only the bubble in the Plumb Vial (D) needs to
be centered.
TIP:
The more accurately you can position the bub-
ble within the vial the more accurate your vertical laser reference
beam will be.
4. Looking over the top of the laser, turn the Plumb Leveling Knob (B)
(which is located on the side of the pivoting laser head in this ori-
entation) to move the bubble within the Plumb Vial (D). Turn the
plumb leveling knob towards the bubble until the bubble is cen-
tered in the vial.
TIP:
Turn the knob in the opposite direction you
need the bubble to move.
5. Use the Plumb Beam Alignment Knob (C )(which is the knob next
to the Plumb Vial) to adjust the plumb laser reference plane over
your mark.
A
B
C
D