AFTER TURNING THE LASER ON, 2 LASER DOTS ARE
PROJECTED FROM THE ROTARY HEAD
The DW073 Cordless Rotary Laser has been designed with dual, side
by side laser diodes. Two diodes allows the laser to avoid blind spots
which could potentially be created by the protective cap over the rotary
head and also produce an extremely bright beam when the rotary
laser head is spun.
THE LASER IS PROJECTING 2 LASER LINES WHEN THE LASER
HEAD IS ROTATED
Take the laser to a DEWALT service center for calibration.
THE POWER LED LIGHT IS FLASHING
,
THE ROTARY HEAD HAS
STOPPED SPINNING AND THE LASER DIODES HAVE SHUT
DOWN.
This indicates that the battery pack needs to be recharged.
TIP:
See
“Removing the Battery Pack” and “Charging Procedures.”
THE BUMP SENSOR WARNING LED LIGHT IS FLASHING
See “Bump Sensor” section for operating instructions.
THE BUMP SENSOR WILL NOT TURN THE LASER OFF AFTER
THE TOOL HAS GONE OUT OF LEVEL
The Bump Sensor is NOT AN OUT OF LEVEL SENSOR. See “Bump
Sensor” section.
THE ROTATING LASER BEAM IS DIFFICULT TO SEE INDOORS
Ambient light conditions will influence the visibility of the laser beam.
To aid in beam visibility, adjust the rotation speed using the ON/OFF
VARIABLE SPEED SWITCH. Remember: Slow Speed = Bright
Beam; Fast Speed = Solid Beam. Wearing the Laser Enhancement
Glasses can also help you see the beam better.
I NEED TO ADJUST THE LASER FOR A VERTICAL / PLUMB ORI-
ENTATION
See “Two-Position Pivoting Head” section.
I NEED TO ADJUST THE LASER FOR MOUNTING ON A WALL
See “Wall Mount” section.
THE LASER ROCKS WHEN POSITIONED ON THE FLOOR
The laser is designed to sit on 3 contact points for maximum stability.
Two of these contact points are stationary while the third is adjustable.
To roughly position the tool on the floor adjust the Base Leveling Knob,
which is located under the battery pack.
I NEED TO STOP THE ROTARY HEAD ROTATION TO DIRECT
THE LASER DOT ONTO A MARK OR TO SET A MARK
See “Manual Head Rotation” section.
THE BUBBLE(S) IN THE VIAL(S) WILL NOT MOVE WHEN
ATTEMPTING TO LEVEL THE LASER
The tool must be positioned on a relatively smooth and level surface
before being leveled. The laser cannot be leveled if the tool is set up
outside of its leveling range.
TIP:
Use the Base Leveling Knob to
roughly level the tool before attempting to level the laser with the lev-
eling knobs.
TIP:
Make sure that the Two-Position Pivoting Head is
locked into either the plumb or level setting before attempting to level
the laser. See “Two-Position Pivoting Head” section.
I CAN ONLY ADJUST THE BUBBLE IN THE PLUMB VIAL WHEN
ATTEMPTING TO PROJECT A VERTICAL LASER LINE
See “Vertical Plumbing” section for instructions on projecting a vertical
laser line.
COLD STORAGE INFORMATION
After storing this product in extremely cold conditions, the laser head
may not immediately rotate when turned on. The rotary head may be
started by depressing and turning the Manual Rotation Button counter-
clockwise.
19
English