AIRMOUNT
®
ISOLATOR
DESIGN PARAMETER WORKSHEET
FOR VIBRATION ISOLATION
A) TO PREVENT OUTGOING VIBRATION TRANS-
MISSION (INTO THE SURROUNDING AREA), OR
B) FOR ISOLATING DELICATE EQUIPMENT FROM
INCOMING VIBRATIONS, PLEASE COMPLETE
THE FOLLOWING:
1. DESCRIPTION OF EQUIPMENT:
2. TYPE OF DISTURBANCE TO BE ISOLATED
(FORCED FREQUENCY OF VIBRATION):
3. MAXIMUM WEIGHT (lbs.)
4. WEIGHT DISTRIBUTION (PLEASE SKETCH ON
GRAPH).
5. DESIRED NUMBER OF MOUNTING POINTS:
6. POSITION OF MOUNTING POINTS (PLEASE
SKETCH ON GRAPH).
7.
SPACE (DIAMETER) AVAILABLE FOR AIRMOUNT
ISOLATORS (inches):
8. AIR PRESSURE AVAILABLE:
9. DIMENSIONS: HEIGHT (inches)
LENGTH (inches)
WIDTH (inches)
10. POSITION OF CENTER OF GRAVITY (C.G., ,
mm UP FROM BASE)
11. DISTURBING FREQUENCY(f
f
)
a) FOR A) ABOVE, MACHINE SPEED, (rpm)
b) FOR B) ABOVE, FREQUENCY OF INCOMING
VIBRATION (H
z
)
12. PERCENT ISOLATION DESIRED (%):
NAME
COMPANY
ADDRESS
CITY/ COUNTRY/CODE
PHONE
FOR ISOLATING AN UNBALANCED MASS
13. PLEASE COMPLETE
1
THROUGH
12
, AND
ALSO INCLUDE:
14. TYPE OF MOVING COMPONENTS (UNBAL-
ANCED MASS):
15. WEIGHT OF UNBALANCED MOVING MASS (lbs.):
16. RADIUS OF MOVEMENT (inches):
17. DIRECTION OF MOVEMENT (PLEASE SKETCH
ON GRAPH).
FOR SHOCK IMPACT ISOLATION
18. PLEASE COMPLETE
1
, AND ALSO INCLUDE:
19. WEIGHT OF MOVING OBJECT (lbs.):
20. SPEED OF MOVING OBJECT (in/sec):
21. DISTANCE OF FREE FALL (inches):
22. DESIRED STOPPING DISTANCE (inches):
23. SPACE (DIAMETER) AVAILABLE FOR SHOCK
IMPACT ISOLATOR(S) (inches):
DATE
Please return to your local stocking distributor, or send directly to:
Firestone Industrial Products Company, 12650 Hamilton Crossing Blvd, Carmel, IN 46032 U.S.A.