Firestone EMDG198 Air Compressor User Manual


 
Description
Assembly Order No.
Blind nut, 1/8 NPT WO2-358-7002
Assembly weight ........................................................ 1.8 lbs.
5
4
3
2
1
0
8 7 6 5 4 3 2
MAX. HT.
11
10
9
8
7
6
5
4
3
2
1
0
Do not use Airstroke in
shaded area without
consulting Firestone
120 Psig
60 Psig
20 Psig
100 Psig
80 Psig
40 Psig
Volume
80 Psig
MIN. HT.
3.5
CONSULT FIRESTONE
BEFORE USING AS
AIRMOUNT
RECOMMENDED
AIRMOUNT
DESIGN HEIGHT
4.5 INCHES
Static Data
8609
HEIGHT IN.
HEIGHT
4.2 MAX O.D.
AT 80 PSIG
15-20 FT. LBS.
TORQUE
3/8-16 THREADED HOLE
(1/2 DEEP)
2.83 DIA.
1/8 NPT
AIR INLET
2.63 DIA.
3/4-16
.87
NOTE: Bellows will not compress properly with less
than 10 PSIG internal pressure.
See page 12 for instructions on how to use chart.
VOLUME (WITHOUT BUMPER) CU IN. x 10
FORCE LBS x 100
Style
7002
Two
Ply
Bellows
Dynamic Characteristics at 4.5 in. Design Height
(Required for Airmount isolator design only)
Volume @ 80 PSIG = 37 in
3
Gage Spring
Pressure Load Rate
(PSIG) (lbs.) (lbs./in.)
40 310 137 124 2.07
60 480 178 114 1.91
80 650 239 114 1.89
100 820 280 110 1.81
Natural
Frequency
CPM HZ
Force Table (Use for Airstroke
®
actuator design)
Volume
Pounds Force
Assembly @ 80
Height PSIG @20 @40 @60 @80 @100
(in.) (in
3
) PSIG PSIG PSIG PSIG PSIG
6.0 50 170 330 510 680 860
5.0 42 150 320 490 660 840
4.0 33 150 310 470 640 800
82
7002