Firestone EMDG198 Air Compressor User Manual


 
57
9 8 7 6 5 4
MAX. HT. MIN. HT.
3
2
1
2
1
2.8
40 Psig
20 Psig
Volume
100 Psig
80 Psig
100 Psig
120 Psig
Do not use Airstroke in
shaded area without
consulting Firestone
60 Psig
RECOMMENDED
AIRMOUNT
DESIGN HEIGHT
6.5 INCHES
Static Data
8829
HEIGHT IN.
224
HEIGHT
3/8-16 BLIND NUTS
(5/8 DEEP)
8.0 MAX O.D.
AT 100 PSIG
2.75
5.31 DIA.
1/4 NPT
AIR INLET
15-20 FT. LBS.
TORQUE
NOTE: A bead plate part is shown. This part is also avail-
able with bead rings. See pages 8-10 for explanation.
See page 12 for instructions on how to use chart.
VOLUME (WITHOUT BUMPER) CU IN. x 100
FORCE LBS x 1000
Dynamic Characteristics at 6.5 in. Design Height
(Required for Airmount isolator design only)
Volume @ 100 PSIG = 171 in
3
Gage Spring
Pressure Load Rate
(PSIG) (lbs.) (lbs./in.)
40 730 361 132 2.20
60 1,130 523 128 2.13
80 1,530 690 126 2.10
100 1,940 849 124 2.07
Natural
Frequency
CPM HZ
Description
Assembly Order No.
Blind nuts, 1/4 NPT WO1-358-3400
Blind nuts, 3/4 NPT WO1-358-3403
Assembly weight ........................................................ 5.0 lbs.
Force to collapse to minimum height (@ 0 PSIG)....... 14 lbs.
Style
224
Two
Ply
Bellows
Force Table (Use for Airstroke
®
actuator design)
Volume
Pounds Force
Assembly @ 100
Height PSIG @20 @40 @60 @80 @100
(in.) (in
3
) PSIG PSIG PSIG PSIG PSIG
7.0 181 320 630 990 1,340 1,710
6.0 160 400 820 1,260 1,700 2,160
5.0 134 470 960 1,490 2,040 2,570
4.0 105 550 1,110 1,720 2,310 2,930
3.0 73 590 1,210 1,860 2,480 3,150