Maintenance
Clean the Gun D
aily
1. Turn OFF (O) the ES On-Off switch.
2. Follow the P
ressure Relief Procedure, page 27.
3. Remove the
air cap/tip guard and spray tip.
4. Flush the gun, see Flushing, page 28.
5. Follow the Pressure Relief Procedure, page 27.
6. Clean the outside of the gun with a compatible
solvent. Use a soft cloth. Point the gun down to
prevent solvent from entering the gun passages.
Do not immerse the gun.
3A2495C 29