Grizzly G0450 Sander User Manual


 
G0449/G0450 37" Drum Sander
-11-
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
G0449
Amperage Draw
The 10 HP motor on the Model G0449 will draw
the following amps:
Main Motor ............................................44 Amps
Feed Motor ...........................................
2
1
/2 Amps
Circuit Requirements
Only connect your machine to a circuit that meets
the requirements below. Always check to see if
the wires and circuit breaker in your circuit are
capable of handling the amperage draw from
your machine, as well as any other machines that
could be operating on the same circuit. If you are
unsure, consult a qualified electrician.
Minimum Circuit Requirement .................60 Amp
Minimum Cord Requirements
A cord is not provided with your machine. For
220V single-phase operation, use the following
type of cord (not to exceed 50 ft.):
Cord ............................................................3 wire
Gauge .................................................... 4 Gauge
SECTION 2: CIRCUIT REQUIREMENTS
Serious personal injury could occur if you
connect your machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
220V Pre-Wired
The Model G0450 is prewired for 220V 3-phase
operation, but can be rewired for 440V 3-phase
operation if needed.
Amperage Draw
The Model G0450 has a 15 HP motor that will
draw the following amps at 220V 3-phase:
Main Motor at 220V ...............................40 Amps
Feed Motor at 220V .............................. 1.3 Amps
Circuit Requirements
Only connect your machine to a circuit that meets
the requirements below. Always check to see if
the wires and circuit breaker in your circuit are
capable of handling the amperage draw from
your machine, as well as any other machines that
could be operating on the same circuit. If you are
unsure, consult a qualified electrician.
Minimum Circuit Requirement 220V ........60 Amp
Minimum Cord Requirements
A cord is not provided with your machine. For
220V 3-phase operation, use the following type
of cord (not to exceed 50 ft.):
Cord ............................................................4 wire
Gauge .................................................... 4 Gauge
G0450 at 220V
A fire may occur if your particular electrical
configuration does not comply with local and
state codes. The best way to ensure compli
-
ance is to check with your local municipality
or a qualified electrician.