Grizzly G0605X/G0606X Saw User Manual


 
G0605X/G0606X Extreme Series 12" Table Saw
-13-
Extension Cords (220V Only)
Using extension cords may reduce the life of the
motor. Instead, place the machine near a power
source. If you must use an extension cord:
Use at least a 10 gauge cord that does not
exceed 50 feet in length.
Ensure that the extension cord contains a
ground wire and plug pin.
Phase Converter Precaution
The power from the manufactured leg may dam-
age electrical components if connected to the
wrong incoming power terminal on your machine.
Only connect the manufactured leg to the L3 ter-
minal (see Page 59 for identification
).
The Model
G0606X can be converted for 440V
operation. This conversion job consists of discon
-
necting the saw from the power source, rewiring
the motor, switching the transformer fuse from
220V to 440V, and changing the thermal overload
relay from 22 to 11 Amps
. Refer to the wiring dia-
gram and photos on Page 60 and 58 for wiring
details.
All wiring changes must be inspected by a quali
-
fied electrician before the saw is connected to the
power source. If, at any time during this procedure
you need help, call Grizzly Tech Support at
(570)
546-9663.
440V Conversion