Grizzly G0619 Drill User Manual


 
G0619 DELUXE SMALL MILL/DRILL
-9-
Figure 2. A 5-15 plug and receptacle.
Serious personal injury could occur if you
connect the machine to the power source
before you have completed the set up pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
110V Operation
Amperage Draw
The Model G0619 motor draws the following
amps under maximum load:
Motor Draw ............................................ 12
Amps
Circuit Recommendations
We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri
-
cian to ensure compliance with wiring codes
. If
you are unsure about the wiring codes in your
area or you plan to connect your machine to a
shared circuit, consult a qualified electrician.
Circuit Breaker .......................................
15 Amps
Plug/Receptacle Type
Included Plug Type ........................... NEMA 5-15
This machine must have a ground prong in
the plug to help ensure that it is grounded.
DO NOT remove ground prong from plug
to fit into a two-pronged outlet! If the plug
will not fit the outlet, have the proper outlet
installed by a qualified electrician.
Extension Cords
We do not recommend the use of extension
cords, if you find it absolutely necessary:
Use at least a 14 gauge cord that does not
exceed 50 feet in length!
The extension cord must also contain a
ground wire and plug pin.
A qualified electrician MUST size cords over
50 feet long to prevent motor damage.
SECTION 2: CIRCUIT REQUIREMENTS
Electrocution or fire could
result if this machine is
not grounded correctly or
if your electrical configu
-
ration does not comply
with local and state codes.
Ensure compliance by
checking with a qualified
electrician!