Grizzly G0771 Saw User Manual


 
-14-
Model G0771 (Mfd. Since 8/15)
4. Use wire nuts to connect the wires as indi-
cated in Figure 8. Twist the wire nuts onto
their respective wires and wrap them with
electrical tape so they will not come loose.
5. Close and secure the motor junction box.
6. Install a 6-15 plug on the power cord, accord-
ing to the plug manufacturer's instructions. If
the plug manufacturer's instructions are not
available, NEMA standard 6-15 plug wiring is
provided on Page 70.
Figure 8. Motor rewired to 240V.
Ground
Connect
Wires
with
Nuts
Here
To Switch
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on Page 70 for your
reference.
IMPORTANT: If the diagram included on the
motor conflicts with the one on Page 70, the motor
may have changed since the manual was printed.
Use the diagram included on the motor instead.
Items Needed Qty
Phillips Head Screwdriver #2 ..................... 1
Electrical Tape ............................ As Needed
Wire Nut (14 AWG x 3) ............................... 1
Plug 6-15 .................................................... 1
Wire Cutters/Stripper .................................. 1
To convert the Model G0771 to 240V:
1. DISCONNECT SAW FROM POWER!
2. Cut off the existing 5-15 plug.
3. Open the motor junction box, then loosen the
two wire nuts indicated in Figure 7.
Figure 7. Inside motor junction box.
Ground
Loosen
These
Wire
Nuts
To Switch
Converting Voltage
to 240V