Harbor Freight Tools 55525 Welder User Manual


 
For technical questions, please call 1-800-444-3353;
Troubleshooting section at end of manual.
Page 16SKU 55525
TO INSTALL A GAS CYLINDER
WARNING: Maximum cylinder height is 1 feet 7 inches (0.5m). Maximum cyl-
inder weight is 22 lb., including gas. NEVER exceed either of these maximums.
CAUTION! Do not use an Argon/Mixed pressure regulator/flow meter with CO
2
shielding gas. To use CO
2
shielding gas, you must install a CO
2
gas pressure regu-
lator/flow meter (neither one included).
Thread the provided strap through the slots on the back of the welder. With assis-
tance, set the cylinder onto the shelf at the back of the welder.
Secure the cylinder in place with the strap.
Remove the protective cap from the cylinder. Stand to the side of the cylinder valve,
and open the valve slightly to blow dust and dirt from the valve. Then, close the
valve.
Make sure the Flow Adjust on the Pressure Regulator/Flow Meter is turned off.
Then, screw the Pressure Regulator/Flow Meter (not included) firmly onto the cyl-
inder valve.
Attach the Gas Line (41) to the Pressure Regulator/Flow Meter from the Gas Inlet
located on the Back Panel (6) of the Welder.
Adjust the flow rate of the gas by turning the Flow Adjust. The typical flow rate is
10-30 CFH (cubic feet per hour). Make sure to check the Welding Wire manu-
facturer’s recommended flow rate.
WARNING
RISK OF EXPLOSION!
While the Gas Cylinder is attached, this unit
must only
be transported using an appropriate welding cart (not
included).
Transporting this welder any other way could result in the
cylinder being damaged or ruptured, causing an explosion
and, potentially, SEVERE PERSONAL INJURY.
1.
2.
3.
4.
5.
6.
7.