14
Parameter tables for user-settable functions follow these conventions:
• Some parameters have 2nd and 3rd motor equivalents, indicated by the
x2xx and x3xx parameter codes in the left-most column.
• Some parameters specify an option code. Where applicable, the
options codes will be in a bulleted list in the Name/Description
column.
• The default values apply to all models unless otherwise noted for each
parameter... –FE2 (Europe) / – FU2 (U.S.) / –FR (Japan).
• Some parameters cannot be edited during Run Mode, and certain
Software Lock settings (B031) can prohibit all edits. If in doubt, place
the inverter in Stop Mode or consult the inverter manual for details.
“F” Group: Main Profile Parameters
Func.
Code
Name / Description
Default Value
–FE2 / –FU2 /
–FR
Set
Value
F001 Output frequency setting 0.00
F002 Acceleration (1) time setting 30.0 / 60.0 /
30.0
F202 Acceleration (1) time setting, 2nd motor 30.0 / 60.0 /
30.0
F003 Deceleration (1) time setting 30.0 / 60.0 /
30.0
F203 Deceleration (1) time setting, 2nd motor 30.0 / 60.0 /
30.0
F004 Keypad Run key routing
• 00Forward • 01Reverse
00