Hitachi L300IP Welding System User Manual


 
16
A021
to
A035
Multi-speed frequency settings
(for both motors)
0.00
A038 Jog frequency setting 1.00
A039 Jog stop mode
00 Free-run stop, jogging disabled during
motor run
01 Controlled deceleration, jogging
disabled during motor run
02 DC braking to stop, jogging disabled
during motor run
03 Free-run stop, jogging always enabled
04 Controlled deceleration, jogging
always enabled
05 DC braking to stop, jogging always
enabled
00
A041/
A241
Torque boost method selection
00 Manual torque boost
01 Automatic torque boost
00
A042/
A242
Manual torque boost value 1.0
A043/
A243
Manual torque boost frequency adjustment 5.0
A044/
A244
V/f characteristic curve selection
00 V/f constant torque
01 V/f variable torque
02 V/f free-setting curve
00 / 01 / 00
A045 V/f gain setting 100.
A051 DC braking enable
00 Disable 01 Enable
00
A052 DC braking frequency setting 0.50
A053 DC braking wait time 0.0
A054 DC braking force during deceleration 0.
A055 DC braking time for deceleration 0.0
A056 DC braking / edge or level detection for
[DB] input
01
A057 DC braking force for starting 0.
A058 DC braking time for starting 0.0
A059 DC braking carrier frequency setting 3.0
A061/
A261
Frequency upper limit setting 0.00
Func.
Code
Name / Description
Default Value
–FE2 / –FU2 /
–FR
Set
Value