6
Stop/Reset Key – Press this key to stop the motor when it is running
(uses the programmed deceleration rate). This key will also reset an
alarm which has tripped.
Parameter Display – A 4-digit, 7-segment display for parameters and
function codes.
Display Units: Hertz/Volts/Amperes/kW/% – These LEDs indicate
the units associated with the parameter display. When the display is
monitoring a parameter, the appropriate LED is ON. In the case of kW
units, both Volts and Amperes LEDs will be ON. An easy way to
remember this is that kW = (V x A)/1000.
Power LED – ON when the power input to the inverter is ON.
Alarm LED – ON when an alarm condition has tripped the inverter.
Clearing the alarm will turn this LED OFF again. See page 9 for details
on clearing alarms.
Function Key – This key is used to navigate through the lists of
parameters and functions for setting and monitoring parameter values.
Up/Down Keys – Use these keys alternately to move up or down the
lists of parameter and functions shown in the display, and to increment/
decrement values.
Store Key – When the unit is in Program Mode and the operator has
edited a parameter value, press the Store key to write the new value to
the EEPROM. This parameter is then displayed at powerup by default.
If you want to change the powerup default, navigate to a new parameter
value and press the Store key.