21
b085 Country code for initialization
• 00 Japan version • 01 Europe version
• 02 US version • 03 (reserved)
01 / 02 / 00
b086 Frequency scaling conversion factor 1.0
b087 STOP key enable
• 00 Enable • 01 Disable
00
b088 Restart mode after FRS
• 00 Restart from 0Hz
• 01 Restart from frequency detected from
actual speed of motor
00
b090 Dynamic braking usage ratio 00
b091 Stop mode selection 00
b092 Cooling fan control
• 00 Fan always ON
• 01 Fan ON during Run, OFF during Stop
00
b095 Dynamic braking control
•00Disable
• 01 Enable during RUN only
• 02 Enable always
00
b096 Dynamic braking activation level 360/
720
b098 • Thermistor for thermal protection control
•00Disable
• 01 Enable – PTC thermistor
• 02 Enable – NTC thermistor
00
b099 Thermal protection level setting 3000
b100 Free-setting V/f frequency (1) 0.
b101 Free-setting V/f voltage (1) 0.0
b102 Free-setting V/f frequency (2) 0.
b103 Free-setting V/f voltage (2) 0.0
b104 Free-setting V/f frequency (3) 0.
b105 Free-setting V/f voltage (3) 0.0
b106 Free-setting V/f frequency (4) 0.
b107 Free-setting V/f voltage (4) 0.0
b108 Free-setting V/f frequency (5) 0.
b109 Free-setting V/f voltage (5) 0.0
b110 Free-setting V/f frequency (6) 0.
b111 Free-setting V/f voltage (6) 0.0
Func.
Code
Name / Description
Default Value
–FE2 / –FU2 /
–FR
Set
Value