OM-1594 Page 11
2-3. Symbols And Definitions
Some symbols are found only on CE products.
Note
A
Amperes
V
Volts Alternating Current
X
Duty Cycle
IP
Degree Of
Protection
Hz
Hertz Circuit Breaker Wire Feed
Jog Output Trigger Gun
Press To Set Increase Trigger Hold On Trigger Hold Off
Purge Spot Weld Time Percent Run-In
Burnback Time
U
1
Primary Voltage
U
2
Load Voltage Read Instructions
I
1
Primary Current
I
2
Rated Current Line Connection
Water (Coolant) In-
put
Water (Coolant)
Output
Fuse
Continuous
Spot Welding
SECTION 3 – INTRODUCTION
3-1. Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed
Speed Range
Wire
Diameter
Range
Welding
Circuit Rating
Overall
Dimensions
Weight
24 Volts AC
Single-Phase
5 Amperes
50/60 Hertz
Constant Voltage (CV)
DC For GMAW Or
Constant Voltage(CV) /
Constant Current (CC) DC
For GMAW-P
All Need 14-Pin And
Contactor Control
70 To 875 ipm (1.8
To 22.2 mpm)
.030 To .062 in
(0.8 To 1.6
mm)
Max Spool
Capacity: 12 in
(305 mm)
All Models: 100%
Duty Cycle, 100
Volts;
Water-Cooled
Models: 400
Amperes,
Air-Cooled
Models: 200
Amperes
Length: 21-1/4 in
(540 mm)
Width: 9-1/2 in
(241 mm)
Height: 16 in
(406 mm)
38 lb