4-17. Adjusting Trigger Hold Actuation Time
To adjust trigger hold actuation
time, proceed as follows:
1 Motor Speed Control Board
PC1
2 Potentiometer R50
. Trigger hold actuation time
range is from 0 to 4 seconds.
To decrease trigger hold actuation
time, use a small nonconductive
screwdriver and rotate
potentiometer clockwise; to
increase actuation time, rotate
potentiometer counterclockwise.
Reinstall side panel.
Tools Needed:
Nonconductive
1/4 in
Ref. 801 557 / 197 716
1
2
Top Of PC1