Ingersoll-Rand HXP50-PE Air Compressor User Manual


 
INSTALLATION / HANDLING
17
SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE, EP50–PE,
HP50–PE, HXP50–PE
DRYER OPTION TECHNICAL INFORMATION 60Hz
General
Refrigerant type R404A
Refrigerant charge
kg (lbs)
1.8 (0.84)
Refrigerant oil Emkarate RL32CF or Texaco Capella HFC32
Control settings
Hot gas setting
barg (psig)
72 – 74 (5.0 – 5.1)
High pressure switch setting
barg (psig)
425 (29.3)
Fan pressure switch setting
on/off
barg (psig)
225 / 175 (15.5 / 12.1)
Performance
(2)
(3)
30 / 40HP 50HP
Dew point temperature at rated
conditions and flow
(3)
41_F (5_C)
(4)
50_F (10_C)
Maximum P across dryer
barg (psig)
2.2 (0.15) 3.0 (0.21)
(1)
In accordance with PNEUROP PN8NTC2.3
(2)
In accordance with ISO 7183 at the modified rated conditions.
(3)
60Hz machines: 85_F ambient, 125 psig inlet.
(4)
40hp 200v unit dewpoint is 50_F (10_C)
http://air.ingersollrand.com