Lincoln Electric C300 CE Welder User Manual


 
B-18
OPERATION
B-18
Press the Left Push Button until Memory 'M' LED
is illuminated.
Rotate center knob to cycle to desired memory.
Press and hold center knob for 5 seconds. The
Set Limits Menu will be active.
POWER WAVE® C300 CE
LIMITS
Limits allow the welder to adjust the welding proce-
dure only within a defined range.
Each user memory may have a different set of limits.
For example, memory 1 can be set to limit the WFS to
200 through 300 in/min, and memory 2 can be set to
limit the WFS to 275 through 310 in/min, while memo-
ry 3 may not have any WFS limits.
Parameters are always constrained by machine limits.
When memory limits are enabled, the parameter will
flash whenever an attempt is made to exceed the
memory limit value. The parameter will not flash if an
attempt is made to exceed the machine limit.
The system machine limits are:
Parameter
Wire Feed Speed
Voltage
Trim
UltimArc™Control
Preflow
Start Time
Run-In WFS
Crater Time
Burnback Time
Postflow Time
Range
Weld mode and wire
feeder dependent.
Weld mode dependent
0.50 to 1.50
-10.0 to 10.0
0.0 to 2.5
0.0 to 10.0
Off, 50 to 150
0.0 to 10.0
0.00 to 0.25
0.0 to 10.0
Units
in/min
Volts
--
Weld mode dependent
Seconds
Seconds
in/min
Seconds
Seconds
Seconds
Limits may be set for:
• Wire Feed Speed/Amperage
• Voltage/Trim
• UltimArcTM Control
Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to mem-
ory before entering the Limits Setup Menu.
+
+
A
Job1
Steel
CV
1.2mm
Ar Mix
V
M
4T
“M Led”
+
+
A
Job1
Steel
CV
1.2mm
Ar Mix
V
M
4T
“M Led”
+
+
A
Job4
Stainless
Pulse
1.0mm
Ar Mix
V
M
4T
+
+
A
Job4
Stainless
Pulse
1.0mm
Ar Mix
V
M
4T
+
+
A
Memory 4
Set Limits
V
M
4T
Press and Hold Knob for
5 second. Limits is active.
+
+
A
Memory 4
Set Limits
V
M
4T
Press and Hold Knob for
5 second. Limits is active.
5 SECONDS
PRESS