Lincoln Electric C300 CE Welder User Manual


 
B-21
OPERATION
B-21
POWER WAVE® C300 CE
EXAMPLE 1 - 2 STEP TRIGGER: Simple operation
The simplest trigger operation occurs with a 2 Step
trigger and the Start, Crater and Burnback functions
all set to OFF. (See Figure B.11)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the welding output and wire is advanced towards
the work piece at the Run-In WFS. If an arc is not
established within 1.5 seconds, the wire feed speed
will jump to the welding wire feed speed
WELD:
The power source output and the wire feed speed
continue at the weld settings for as long as the trigger
is pulled.
POSTFLOW: As soon as the trigger is released, the
power source output and the wire feed speed are
turned OFF. Shielding gas continues until the post
flow timer expires.
Shielding
Gas
IdlePreflowRun-InWeldPostflowIdle
Power
Source
Output
WFS
On
Off
Run-in
Off
Weld
Off
Weld
Arc
Established
Trigger
Pulled
Trigger
Released
2 Step Trigger
Start = OFF
Crater = OFF
Burnback = OFF
1.5 sec max.
Shielding
Gas
Idle Preflow
Run-In
Weld Postflow Idle
Power
Source
Output
WFS
On
Off
Run-in
Off
Weld
Off
Weld
Arc
Established
Trigger
Pulled
Trigger
Released
2 Step Trigger
Start = OFF
Crater = OFF
Burnback = OFF
1.5 sec max.
FIGURE B.11