&')+ &%
'&.)S$* %#. ))
,*)$$&) *
)753>>3?7?ADKI;F:?7?ADK4GFFA@E
To recall a user a memory, press one of the six user
memory buttons. The memory is recalled when the
button is released. Do not hold the button for more
than two seconds when recalling a user memory.
)753>>3?7?ADKI;F:F:79G@FD;997D
If desired, memories 2 through 6 can be recalled with
the gun trigger. For example, to recall memory 3,
quickly pull and release the gun trigger 3 times without
welding.
Note: the Power Feed™ 10M Single Wire Feeder is
factory set with this feature disabled. Use the SETUP
menu and change P.4 to enable memory recall with
the gun trigger.
*3H73?7?ADKI;F:?7?ADK4GFFA@E
To save a memory, press and hold the desired memo-
ry button for two seconds. When the button is initially
pressed, the corresponding LED will illuminate. After
two seconds, the LED will turn off. Do not hold the
button for more than 5 seconds when saving a user
memory.
Note that memories may be locked in the Setup menu
to prevent accidental overwrite of the memories. If an
attempt is made to save a memory when memory sav-
ing is locked, the message "Memory save is
Disabled!" will appear briefly in the MSP4 display.
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUNB
1
4
2
5
3
6
M
M
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUN B
1
4
2
5
3
6
M
M
&'+ &%#,#')&,)$$&)0
'%#&')+ &%
The Dual Procedure/Memory Panel performs three
functions:
• Weld procedure selection
• Memory save and recall
• Limits setting
There are two procedure memories (A and B) and six
user memories (1-6).
'DA576GD7$7?ADKHE,E7D$7?ADK
Procedure memory is used while welding. Changes to
the weld procedure (WFS, voltage, arc control, etc.)
immediately change the contents inside the selected
procedure memory. Procedure memory saving is
done automatically.
User memories work by copying the weld procedure
from one of the six memories into either the A or B
procedure. Weld procedures are saved into the mem-
ories only when the operator chooses.
,E;@9'DA576GD7$7?AD;7E
Procedure memories can be selected by choosing
either "A" or "B" procedure directly with the memory
panel, or by selecting "GUN" and using a dual proce-
dure gun to select between procedure "A" and "B".
When selecting procedures with the gun switch, "A" or
"B" will flash to show which procedure is active.
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUNB
1
4
2
5
3
6
M
M
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUN B
1
4
2
5
3
6
M
M
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUNB
1
4
2
5
3
6
M
M
HOLD 2 SECONDS TO SAVE
PROCEDURE
MEMORY
A
GUN B
1
4
2
5
3
6
M
M
RECALL
PRESS 1
SECOND
SAVE
PRESS 2
SECONDS
PROCEDURE
MEMORY
PRESS TO
SELECT
PROCEDURE
USER
MEMORIES
ON
ON
'*. +*++ %*
VS9W Switch on M20122-1 P.C. board Memory Panel
showns that Dip Switchs are in the &% position. (See
Below)
Dip Switch on
P.C. board.
(Single Head
Feeder)