Lincoln Electric SVM169-A Welder User Manual


 
PRECISION TIG 185
TROUBLESHOOTING & REPAIR
F-8 F-8
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING GUIDE Observe Safety Guidelines
detailed in the beginning of this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.
TIG MODE PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
Machine output is intermittently lost.
Gas flow and high frequency are
also interrupted.
1. The problem may be caused by
high frequency interference.
Make sure that the machine is
grounded properly according to
the installation instructions. If
there are other high frequency
sources in the area, make certain
that they are grounded properly.
2. Make sure the Amptrol is operat-
ing properly.
3. Check to make sure that the
input voltage is correct for the
machine reconnect configuration.
Refer to Reconnect Procedure
in the Installation section of this
manual.
1. Check for loose or faulty connec-
tion on the leads between the
remote receptacle and plug J5
on the control board. See wiring
diagram.
2. Check the plugs on the control
board for loose connections.
3. The control board may be faulty.