Lincoln Electric SVM169-A Welder User Manual


 
PRECISION TIG 185
TROUBLESHOOTING & REPAIR
F-34 F-34
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
DC TIG MODE
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
• Perform High Frequency Disable Procedure.
____________________________________________________________________
10 V
2 ms
0 V
MACHINE LOADED TO 180 AMPS AT
16VDC.
This is the typical DC (+) output voltage
waveform generated from a properly operat-
ing machine. Note that each vertical division
represents 10 volts and that each horizontal
division represents 2 milliseconds in time.
The machine was loaded with a resistance
grid bank. The grid load meters read 180
amps and 16VDC
Note: Scope probes connected at machine
output terminals: (+) probe to electrode, (–)
probe to work.
Volts/Div. ...............................10 V/Div.
Horizontal Sweep .................2 ms/Div.
Coupling.........................................DC
Trigger .....................................Internal
SCOPE SETTINGS