Lincoln Electric SVM169-A Welder User Manual


 
PRECISION TIG 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
A-2
INSTALLATION
A-2
TECHNICAL SPECIFICATIONS - PRECISION TIG 185 (K2345-1AND K2347-1,-2)
Volts at Rated Amperes
15.2 V AC/DC
14.1 V AC/DC
13.8 V AC/DC
27.4 V AC/DC
23.6 V AC/DC
Type of Output
CC (Constant Current)
AC/DC
Amps
185A AC/DC
90A AC/DC (BAL)
70A AC (AUTO-BAL)
185A AC/DC125
90A AC/DC
Maximum Open
Circuit Voltage
(STICK AND TIG)
AC OCV: 75
DC OCV: 59
Input Current at Rated Output
35A / 32A Effective
and 70A / 64A Maximum
Duty Cycle
GTAW 15% Duty Cycle
100% Duty Cycle
SMAW 15% Duty Cycle
100% Duty Cycle
Output Current
Range
7-185 Amps (AC)
5-185 Amps (DC)
Standard Voltage
208/230/1/60
INPUT - SINGLE PHASE ONLY
OUTPUT RANGE
RATED OUTPUT
Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle)
(Example; 110A@60% for AC/DC Stick and Balance TIG)
Using standa
r
d #8-3 input cable for protec
t
ed
(1)
input supply
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
50 70 90 110 130 150 170 190
208/230v Model: AC/DC Stick & DC TIG
(AC TIG with #6-3 input cable)
460/575v Model: AC/DC Stick & AC/DC TIG
380/415v Model: AC/DC Stick &
DC/AC Auto-Bal.TIG
208/230v Model: AC TIG using 230v input
380/415v Model: AC TIG (Max. Penetration)
208/230v Model: AC TIG using 208v input
OUTPUT AMPS
OUTPUT % DUTY CYCLE
(1)
Wiring and protection based on the 2002 U.S. National Electric Code:
Use a Super Lag type fuse or circuit breaker with a delay in tripping action.
Models with NEMA 6-50P plug may be used with a 50 amp protected 6-50R receptacle, or
with a maximum 70 amp protected 6-50R receptacle if dedicated for the welder.