Lincoln Electric SVM 117-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
WIRE-MATIC 250
Duty Cycle Amps Volts at Rated Amps
100% 145 amps 26
60% 200 amps 28
35% 250 amps 26
Current Range Maximum Open Circuit Voltage Wire Speed Range
30A - 250A 40V 50 - 600 IPM
(1.27-15.2 m./minute)
Input Voltage/ Fuse (Superlag) Type 75
0
C wire in Type 75
0
C Copper
Frequency or Breaker Size Copper conduit AWG Ground Wire in Conduit
(IEC Sizes)
Runs to Runs over
100ft. (30m.) 100ft. (30m.)
208/60 60 8 (10mm
2
) 6 (16mm
2
) 10 (6mm
2
)
230/60 60 10 (6mm
2
) 8 (10mm
2
) 10 (6mm
2
)
460/60 30 14 (2.5mm
2
) 12 (4mm
2
) 10 (6mm
2
)
575/60 25 14 (2.5mm
2
) 12 (4mm
2
) 10 (6mm
2
)
HEIGHT Width DEPTH WEIGHT
(W/GUN)
28.2” 18.8” 40.1” 220 lbs.
(719mm) (480mm) (1019mm) (100 Kg.)
Standard Voltage Input Current at Rated Output
208/230/1/60 53/49 Amps
230/460/575 50/25/20 Amps
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS - Wire-Matic-250
INPUT - SINGLE PHASE/ 60 HERTZ ONLY
RATED OUTPUT
OUTPUT
PHYSICAL DIMENSIONS
STORAGE OPERATING
±40
0
C -20
0
C to 40
0
C
OPERATING TEMPERATURE
RECOMMENDED INPUT WIRE & FUSE SIZE