14.3 Listing of Global Messages
Error
Code
Message Description
Canceling and Re-
pairing Method
141
3518
DIRECTORY FULL At most 254 programs can be stored, for
the file manager built in control enables
the registration of 254 programs in the di-
rectory. This message is displayed, if more
programs are to be registered during pro-
gram execution by the use of command
POPEN.
This does not necessarily mean, that the
memory is full.
The message is can-
celed by RESET
key.
If a new program is
to be opened one of
the unnecessary old
ones have to be de-
leted.
3519
MEMORY FULL This message is displayed by the NC, if
the storage built in control is full during
program execution as the effect of
command BPRNT or DPRNT.
The message is can-
celed by RESET
key.
One of the unneces-
sary old ones have to
be deleted.
3520
FILE NOT EXISTS If data is to be sent by means of command
DPRNT or BPRNT and no channel is
open with command POPEN.
The message is can-
celed by RESET
key.
3524
FILE NOT OPEN If an NC action refers to a file not open. The message is can-
celed by RESET
key.
It is not the user’s
fault, the operator
cannot repair it.
3528
INVALID ERROR CODE If invalid error code has been generated
while managing a file.
The message is can-
celed by RESET
key.
It is not the user’s
fault, the operator
cannot repair it.
3530
SYSTEM ERROR Internal communication error of the NC
supervisor program.
The message is can-
celed by RESET
key.
It is not the user’s
fault, the operator
cannot repair it.
3545
MACRO TABLE BAD If checksum of the memory area
containing macro variables #500...#599,
preserved upon power-off is false.
The message is can-
celed by RESET
key.
The table of macro
variables must be
reorganized.