Porter-Cable 3802L Saw User Manual


 
Use proper extension cords. Make sure your extension
cord is in good condition. When using an extension
cord, be sure to use one heavy enough to carry the
current of the machine. An undersized cord will cause a
drop in line voltage, resulting in loss of power and
overheating. Fig. D, shows the correct gauge to use
depending on the cord length. If in doubt, use the next
heavier gauge. The smaller the gauge number, the
heavier the cord.
Fig. D
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 120
up to
25 18 AWG
0-6 120 25-50 16 AWG
0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120
up to
25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120
up to
25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120
up to
25 14 AWG
12-16 120 25-50 12 AWG
12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of
the same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the machine.
DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.
POLARIZED PLUGS: To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider than
the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
MOTOR
Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus
or minus 5 percent of that shown on the specification plate of the tool. Several models, however, are designed for A.C.
current only. Refer to the specification plate on your tool for proper voltage and current rating.
Do not operate your tool on a current where the voltage is not within correct limits. Do not operate tools
rated A.C. on a D.C. current. To do so may seriously damage the tool.
REPLACEMENT PARTS
When servicing, use only identical replacement parts.
POWER CONNECTIONS
6
FOREWORD
Porter-Cable Model 3802L is a high capacity, 12" compound laser miter saw designed to cut wood and non-ferrous
metals. This unit incorporates the latest technology DUAL LASERLOC
line-of-cut indicator feature. It can crosscut 8"
x 2¼" and 7" x 3¼", miter at 45° both left and right 5¼" x 2¼", bevel at 45° left 6¼" x 2¼" and 8" x 1¼", and compound
45° x 45°, 5¼" x 2 1/2" and 4¼" x 2¼". It has positive miter stops at 0°, 15°, 22.5°, 31.62°, and 45° both left and right,
and bevel stops at 0° and 45° left.
NOTICE: The photo on the manual cover illustrates the current production model. All other illustrations
contained in the manual are representative only and may not depict the actual color, labeling, or accessories,
and are intended to illustrate technique only.
FUNCTIONAL DESCRIPTION
EXTENSION CORDS