Powermatic PWBS-14CS Cordless Saw User Manual


 
9
The 115V attachment plug (shown in Figure 6) supplied with the band saw, must be replaced with a
UL/CSA listed plug suitable for 230V operation (shown in Figure 7). Contact your local authorized Walter
Meier (Manufacturing) Inc., service center or qualified electrician for proper procedures to install the plug.
The band saw must comply with all local and national codes after the 230 volt plug is installed.
The band saw with a 230 volt plug should only be connected to an outlet having the same configuration
(see Figure 7). No adapter is available or should be used with the 230 volt plug.
Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly
grounded. If you are not sure, have a registered electrician check the receptacle.
NOTE: The lamp is designed for use with 115V power. If the saw is converted to 230V, discontinue
use of the lamp, and use an alternate lamp with an independent electrical source.
Figure 4 Figure 5
Figure 6 Figure 7
Extension Cords
If an extension cord is necessary, make sure the cord rating is suitable for the amperage listed on the
machine’s motor plate. An undersized cord will cause a drop in line voltage resulting in loss of power and
overheating.
Use the chart in Figure 8 as a general guide in choosing the correct size extension cord for the band saw.
If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
Recommended Minimum Gauge (AWG) of Extension Cords
Ampere Rating
Volts Total Length of Cord in Feet
115 V 25 ft. 50 ft. 100 ft. 150 ft.
230 V 50 ft. 100 ft. 200 ft. 300 ft.
A
WG
< 6 18 16 16 14
6 to 10 18 16 14 12
10 to 12 16 16 14 12
12 to 16 14 12 Not recommended Not recommended
Figure 8