Q-Logic ISR6142 Router User Manual


 
4 – Installation
iSR6142 Router Installation
SN0051102-00 A 4-9
A
Connect the Router to AC Power
To power up the router, connect the power cord to the power receptacle on the
router chassis and to a grounded AC outlet. The router responds in the following
sequence:
1. The chassis LEDs (input power, heartbeat, system fault) light up, then all
port LEDs light up.
2. After a couple of seconds the heartbeat and system fault LEDs go off, while
the input power LED stays on. The router is executing the POST.
3. The POST completes after about 45 seconds and the heartbeat LED starts
flashing at a one second rate. If an error has occurred, the System Fault
LED will blink a pattern that indicates the fault reason. For more information
about error blink patterns, see page 5-3.
WARNING!!
This product is supplied with a three-wire power cable and plug for the
user’s safety. Use this power cable in conjunction with a properly grounded
outlet to avoid electrical shock. An electrical outlet that is not correctly wired
could place hazardous voltage on metal parts of the router chassis. It is the
customer’s responsibility to ensure that the outlet is correctly wired and
grounded to prevent electrical shock.
You may require a different power cable in some countries because the plug
on the cable supplied with the equipment will not fit your electrical outlet. In
this case, you must supply your own power cable. The cable must meet the
following requirements:
For 125 Volt electrical service – the cable must be rated at 10 Amps and
be approved by UL and CSA.
For 250 Volt electrical service – the cable must be rated at 10 Amps,
meet requirements of H05VV-F, and be approved by VDE, SEMKO, and
DEMKO.