Shindaiwa DGW310MC Welder User Manual


 
19
6-5 Battery
Caution: Injuries to eye and skin
Battery Fluid contains diluted sulfuric acid. Avoid contact
with eyes, skin or clothing.
If the acid comes to contact, especially with eyes, flush with a lot of water and contact to a doctor
immediately.
Caution: Explosion
Do not use the equipment or charge the battery in the case battery
Fluid level is lower than the LOWER level.
Battery emits some combustible gas, so keep it away from fire and spark.
1. Check the fluid level. If the level is near or
lower than the LOWER level, add distilled
water until the fluid level reaches UPPER.
2 Make sure that the battery cables are firmly
secured to the posts.
Tighten the clamps if it is necessary.
Caution
Check the hydrometer of the battery fluid. If it falls below 1.23, the battery requires recharging. Consult
with our authorized distributor or our service department.
Replacing battery
1. Remove the under plate.
(M6 bolt x 2)
2. Remove the cable on - side.
(Always on + side first)
3. Remove the battery fixing plate.
4. Remove the cable on + side.
5. Remove the battery.
Reinstall a new battery in the reverse order.
(Install always the cable to the + positive post first in a new battery.
Caution
Use the following battery. 46B24L
When replacing a battery, remove the under plate firstly. Otherwise the battery slanted and the fluid
may leak and contact to eye or skin.
Ins Cap
+ terminal
Terminal
Fix Plate
Under Plate
Lower level
Upper level
Terminal